PicoScope Automotive Diagnostic Oscilloscope
|
 
 
 
PicoScope Automotive Diagnostic Oscilloscope
  • Up to 400 MS/s real-time sample rate
  • 20MHz bandwidth
  • 250,000,000 sample memory
  • ±200 V input range
  • Floating inputs
  • ConnectDetect™ for reliable connections
  • No external power supply required
  • USB 3.0 connection for faster screen updates
  • Protected against overloads and short circuits
  • Easy to use with any vehicle

IncludesPicoScope Automotive Software

When you buy a PicoScope Automotive Oscilloscope you get industry-leading performance that is both affordable and easy to use. With the introduction of the PicoScope 4425 and 4225, performance has been upgraded - but the price remains the same!

Pico automotive oscilloscopes are used by more than twenty of the world's leading vehicle manufacturers, and in thousands of workshops to save time and money by making it easier and quicker to diagnose faults.

Which Diagnostics Kit is Right for Me?
Compare Kits

$1655.00*

 PicoScope 4425APicoScope 4225A

 

What does it all mean?

The main specifications explained.

 

Vertical Resolution

The number of dots in the waveform from top to bottom. '12 bits' means 4,096 dots, which is more detail than you can see on the screen all at once. PicoScope stores the extra detail for when you zoom in.

 

Buffer Memory

The number of dots in the waveform from left to right. If you don't have enough memory then the waveform won't show all the detail in the signal. PicoScope has more than enough memory, so you can zoom in thousands of times and still see a clear display and spot intermittent glitches.

 

Waveform Buffer

A memory that collects your most recent waveforms. If a waveform disappears off the screen, you can look back through the waveform buffer to find it.

 

Trigger

This ensures that the scope captures the waveform at the right time and keeps it in a stable position on the screen. PicoScope can set up the trigger automatically, but if you want you can select special trigger modes to catch unusual waveforms that you might otherwise miss.

 

Bandwidth

For faster signals, more bandwidth gives a more faithful reproduction of the signal shape on the screen. PicoScope has enough bandwidth to display CAN bus and FlexRay signals accurately.

 

Sampling Rate

Like bandwidth, this is more important for fast signals. A high sampling rate ensures that you catch the high-frequency details of the signal.

 

Channels42
Vertical Resolution12 bits (16 bits in enhanced resolution mode)
DC Accuracy±1% of full scale (2% on 50mV range)
Sensitivity10 mV/div to 40 V/div
Input Ranges (full scale)±50 mV to ±200 V in 12 ranges
Input Impedance1 MΩ in parallel with 24 pF
Input TypeFloating single-ended BNC connector
Input CouplingSoftware selectable AC/DC
Input Overvoltage Protection±250 V (DC + AC peak)
Buffer Memory250 M samples shared between active channels
Waveform BufferUp to 10,000 waveforms
Timebase Ranges5 ns/div to 5000 s/div
Bandwidth20 MHz (10 MHz on ±50 mV range)
Maximum Sampling Rate (single shot)
1 channel in use
2 channels in use
3 or 4 channels in use

400 MS/s
200 MS/s
100 MS/s
Triggers
SourceAny input channel
Basic TriggersAuto, repeat, single, none
Advanced TriggersRising edge, falling edge, edge with hysteresis, pulse width, runt pulse, dropout, windowed, logic
Maximum Pre-Trigger DelayUp to 100% of capture length
Maximum Post-Trigger DelayUp to 4 billion samples
Spectrum Analyser
Frequency RangeDC to 20 MHz
Display ModesMagnitude, peak hold, average
Environmental
Operating Temperature Range0 °C to 40 °C (15 °C to 30 °C for quoted accuracy)
Operating Humidity Range5% to 80% RH, non-condensing
Storage Temperature Range-20 to +60°C
Storage Humidity Range5 to 95% RH, non-condensing
Physical Characteristics
Dimensions190 x 160 x 40 mm (approx 7.5 x 6.3 x 1.6 in)
Weight<900 g (approx 2 lb)
General
Additional Accessories (supplied)USB 3.0 cable, user manuals, software CD-ROM
PC InterfaceUSB 3.0 (USB 2.0 compatible)
Power RequirementsPowered from USB port
ComplianceFCC (EMC), CE (EMC and LVD), RoHS compliant