DW6090 Single Phase Portable Power Analyser
|
 
 
 
DW6090 Single Phase Portable Power Analyser
  • Multifunctional True RMS Autoranging Meter
  • Measure Watts, VA, WHr, PF, Hz and more
  • Super Large LCD simultaneously displays Watts, Power Factor, Frequency, Voltage and Current
  • Measure Current by Direct Input or via a Current Clamp or CT
  • True AC Power (Watts) and Apparent Power (VA) with Hi & low Alarm Setpoints
  • RS232 Interface with PC Software (U232)
  • AC Adaptor or Battery Powered
$681.00*

Volts:DC: 0.1V to 600V ±(1% + 1 Dgt)
AC: True RMS 1V to 600V ±(1% + 1 Dgt)
@ 40 to 400Hz
Resistance:1Ω to 19.99kΩ ±(1% + 1 Dgt)
Frequency:0.1Hz to 999Hz ±(1% + 1 Dgt)
Power Factor:0.01 to 1* ±(1.5% + 2 Dgts)
Watt Hours:0*1 WHr to 9999 kWHrs ±(1.5% + 5 Dgts)
 
Current:DirectVia ClampVia CT (100/5 or 1000/5)Accuracy
DC10mA to 15A1A to 1000AN/A
±(1% + 3 Dgts) excl. adaptors
True RMS AC10mA to 15A1A to 1000A0.1 to 1000A±(1% + 1 Dgt) excl. adaptors **
Power:    
Watts1W to 6kWN/AN/A±(2% + 2 Dgts) **
VA0.01VA to 9999VA1W to 999.9kW1W to 999.9kW(1% + 1 Dgt) excl. adaptors **
** @ 110V/220V +15%, 40 to 400Hz
 
Other Functions:Autoranging, Peak Hold and Data Hold
Dimensions:90(H) x 210(W) x 280mm, 1.6kg
Power Supply:6 x 1.5V AA Batteries (Not included) or optional 9V/500mA Adaptor
Accessories Included:Test Leads, PC interface and U232 Software