Accuracy and Resolution Although accurate temperature sensors are widely available, it has been difficult to take advantage of these due to errors caused by the measuring device. The PT-104 however, is inherently accurate due to its innovative design. Rather than relying on voltage references (which tend to be temperature sensitive) it uses ‘reference’ resistors which are extremely stable (low temperature co-efficient and drift). The exact value of each resistor is stored in an EEPROM to provide the ultimate in accuracy (yearly re-calibration is recommended). A high-performance 24-bit ADC is used to achieve the 0.001°C* resolution. Temperature The PT-104 measures temperature using platinum resistance thermometers (PRTs). Both common industry standards (PT100 and PT1000) are supported. The unit is compatible with 2, 3 and 4 wire sensors (4 wire PT100 sensors are recommended for better accuracy – especially for longer probe cable lengths). A wide range of PT100 sensors is available for use with your PT–104. Resistance When measuring resistance, the unit uses a four-wire circuit to give the greatest possible accuracy. Two resistance ranges are available (0 to 375 Ohms and 0 to 10,000 Ohms). The unit is calibrated for 0 to 375 Ohms so this range should be used for accurate measurements. Software Your PT104 data logger is supplied with PicoLog data logging software. PicoLog will automatically detect which sensor is connected and will display readings in the correct units. Also supplied is a software development kit. The SDK contains a range of software drivers and example code that you can use to write your own software or to use your PT-104 data logger with third-party software. PT100 Probes and Sensors These four wire Platinum Resistance Probes are top quality PT100 temperature sensors designed for high accuracy and long life. Plugs are compatible with the PT104 Logger and incorporate moulded strain relief. Applications covered are general purpose, immersion, standard and heavy duty insertion and standard and high temperature air measurement. The sensors in the table below comply with BS1904. The class A (DIN 43760) sensors offer an accuracy of ±0.15° at 0°C. For increased accuracy we also offer the SE012, tenth-DIN sensor (±0.03° at 0 °C). Please note that these accuracy specifications relate to the SENSOR ONLY. To determine overall measurement system accuracy, always add the sensor error to that of the PT104. Need to measure more channels? Create your own custom data acquisition system with the PicoLog 1000 multi-channel data logger. |
$1267.00*
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Quoted accuracy is for options marked *
PT104 Single Channel Screw Terminal Adaptor
SE011 General Purpose PT100 Probe
SE012 High Accuracy PT100 Immersion Probe
SE014 PT100 Immersion Probe
SE015 PT100 Insertion Probe
SE016 Heavy Duty PT100 Insertion Probe
SE017 Fast Response PT100 Air Probe
SE018 High Temperature PT100 Air Probe
SE019 Economy PT100 Probe |